Power: |
10 -16 VDC ( 110/220
VAC 50/60 Hz optional ) |
|
Ranges:
|
HC: 0 - 2000 ppm
CO: 0 - 10%
CO2: 0 - 20%
O2: 0 - 25%
NO: 0 - 5000 ppm ( Nitric Oxide )
|
|
Warm up: |
Less than 10 minutes
|
|
Display resolution: |
HC: 1 ppm vol.
CO: 0.01% vol.
CO2: 0.1% vol.
O2: 0.01% vol.
NO: 1ppm* |
|
Digital display: |
3” x 5” LCD Displays all 5
gases, & AFR or LAMDA |
Accuracy
( Bar 97 EPA ASM ) |
HC: 4 ppm HC
CO: 0.06% CO
CO2: 0.3% CO2
O2: 0.1% O2
NO: 25 ppm |
|
Drift: |
Zero and span drift are
less than ± 0.6% of full scale for the
first hour and less than ± 0.4% of full
scale per hour thereafter. |
|
Response time: |
Bench: 1.5 Sec/25 ft. hose
5 sec. to 90% of final reading |
|
Ambient conditions: |
35F (2C) to 120F (45C), rel.
humidity 0-98% |
|
Sample hose:
|
25 feet ( 7.5 m) with QD
coupling /200 F Degrees Max. |
|
Sample probe:
|
Stainless steel 1200
Degrees F ( replaceable flex tip ) |
|
Mass: |
Approx.: 10 LBS. ( 4.5 Kg ) |